Your shopping cart is empty!
Availability: In Stock
The OMD-2008 Bilge Alarm Monitor was designed by Deckma Hamburg GmbH for use in conjunction with 15ppm Oily Water Separator Systems. The performance and specifications of the OMD-2008 comply with IMO Resolution MEPC.107 (49). The OMD-2008 Bilge Alarm Monitor is made up of 2 main components: the Computer Unit and the Measuring Cell. The Computer Unit contains the display PCB with the data logger and the terminals for external connections. The Measuring Cell contains optics and electronics and is connected to the computer unit via a data cable. The Computer Unit and Measuring Cell are mounted onto a stainless steel support that holds the Valve Assembly. The valve’s handle controls sample water flow and clean water usage. Separate mounting plates for the Computer Unit & Measuring Cell with Valve are available upon request.
Specifications
Property
Value
Range (measurement & indication)
0 - 30 ppm, Trend up to 50ppm
Range (IMO specification)
0 - 15 ppm (according IMO regulations)
Accuracy
better than IMO MEPC.107(49)
Electrical power supply
24V - 240V, AC or DC, Automatic Voltage Selection
Electrical power consumption
< 10 VA
Sample
Oily water from separator outlet, 0,1 - 4 l/min
Sample temperature range
+1°C to +65°C
Alarm 1 & 2 Set Points
1 - 15ppm (independently adjustable)
Alarm 1 operating delay for annunciation
1 - 540 sec
Alarm 2 operating delay for control
1 - 10 sec
Alarm contacts
2 independently adjustable switchover contacts
Alarm contact operation mode
De-energized in Alarm State
Alarm contact ratings
3A, 240V each
Alarm output
0 - 20 mA or 4 - 20 mA, for 0-30ppm reversible, ext. Load<150Ω
Display
Graphic Display
Ambient temperature
+1°C to +55°C
Class of protection
IP 65
Dimension
360 x 240 x 100 mm (WxHxD)
Weight
5,4 kgs
Measuring MethodThe FOCAS-1800 using a full optical continuous measuring method* can sure grasp ch..
$0.00 Ex Tax: $0.00
DescriptionFOCAS-1500c Bilge Alarm serves to continuously measure the concentration of oil in the ..
Oil Mist detection, now widely accepted as a means of providing early warning of incipient bearing ..
The Graviner Mk6 OMD is an analogue addressable oil mist detection system, capable of monitoring up..
A 15ppm Bilge Alarm is normally used in connection to a ship's oil filtering equipment (also known ..
The OMD-2005 Bilge Alarm Monitor was designed by Deckma Hamburg GmbH for use in conjunction with 15..
The OMD-11 Bilge Alarm Monitor is an older unit, designed by Deckma Hamburg GmbH, for use in conjun..
The OMD-32 Oil-in-Water Monitor has been designed specifically for use in conjunction with oil-wate..
The OMD-21, 15ppm Bilge Alarm exceeds the requirements of IMO Resolution MEPC. 60 (33). With ..
..