The HERMetic
UTImeter Rtex is a portable liquid level gauge designed for restricted gauging
of petroleum products. The unit is used
for custody transfer, inventory control measurement and free water detection on
marine vessels and shore tanks. The HERMetic UTImeter Rtex has to be connected
to a HERMetic vapour control valve fixed on the tank.
The unit
enables 3, optionally 4 measurements in one single operation:
• Ullage
• Temperature
• Oil-Water
interface level
• Innage,
Reference height (Visc version)
Specifications
Accuracy
of ullage-interface detection |
± 2 mm (± 0.08” approx.) |
Ullage,
interface indication |
Audible and Visible selectable |
Tape
length |
15
m/50 ft, 30 m/100 ft, 35 m/115 ft |
Tape
graduation |
Metric/English |
Tape
resolution |
1
mm / 1/16” |
Tape
accuracy |
± 1.5 mm/30 m (±1/16”/100 ft
approx.) |
Meets
API MPMS Chap 3.1A and ISO 4512 requirements |
|
Temperature
accuracy |
± 0.1°C (0°C to 70°C) |
Meets
API MPMS Chap 7 request |
±
0.2°F (32°F to 158°F) |
Meets
ISO 4268 , IP PMM Part IV |
|
Ambient
temperature range |
-20°C
to 50°C / (-4°F to 122°F) |
Temperature
sensor measurement range |
-40°C to 90°C / (-40°F to 194°F) |
Temperature
measurement resolution |
0.01°
or 0.1° selectable |
Temperature
reading |
°C or °F selectable |
LCD
Display |
8
characters with backlight |
Power |
Approved 9V batteries |
Weight
with 15 meter / 50ft tape |
3.7
kg / 8.1 Lbs. |
Hazardous
environments approvals |
|
ATEX |
II
1 G Ex ia IIB T4 / Tamb 50°C |
Factory
Mutual |
CL I, DIV 1, C&D, T4 Tamb 50°C
and CL I ZN 0, AEX IIB T4 Tamb 50°C |
IECEx
|
Zone
0, Ex ia IIB T4 |
Related Products
Hermetic UTI meter Gtex
The HERMetic UTImeter Gtex is a portable gas tight liquid level gauge designed for closed gauging ..
$120.00 Ex Tax: $120.00
MMC Oxygen Sensor Gauging Tape System for Petroleum Tankers and Inland Barge
The MMC Flexi-Dip Oxygen Sensor Gauging Tape is a battery-operated electronic system feat..
$120.00 Ex Tax: $120.00
Hermetic UTI MK3 LBI UNI
Restricted and Open Gauging Tapes provide a convenient and accurate means for measuring ullage, pr..
$120.00 Ex Tax: $120.00
MMC Flexidip CLOSED Gauging Tape
MMC’s Flexi-Dip closed (FIPS) sampling and sounding system for petroleum and chemical tanks is des..
$200.00 Ex Tax: $200.00
MMC Flexidip Restricted and Open Gauging Tape
FLEXI-DIP Gauging Tapes (Restricted and Open) Restricted and Open Gauging Tapes provide a convenien..
$0.00 Ex Tax: $0.00
Hermetic UTI meter Gtex 2000
The HERMetic UTImeter Gtex 2000 is a portable Gas tight liquid level gauge designed to be..
$0.00 Ex Tax: $0.00