Your shopping cart is empty!
Availability: In Stock
The Graviner Mk6 OMD is an analogue addressable oil mist detection system, capable of monitoring up to 64 detector heads fitted on up to 8 engines. This is achieved without sample pipes and with minimum cabling. Each detector head monitors a single crankspace and is a stand-alone device. When assigned a unique address and supplied with 24V DC it gathers oil mist density data and converts it to a digital signal for transmission via the data cable to the control unit.
Specifications
Construction
Detector
Black Zytel 70G30 Nylon 66
Junction Box
Cast Aluminium Control
Unit
Painted mild steel enclosure
Response time
Less than 1.2 seconds for a 64 detector system
Sensitivity
Detects average crankspace oil mist densities between 0.3mg/l and 1.3mg/l. Easily adjustable by customer to suit individual engine (lower explosion limit 30 - 50mg/l depending upon oil type). Detects variation of individual crankspace densities from the average of between 0.05mg/l and 0.5mg/l (simple adjustment by customer).
Operating Temperature
Detector and Junction Box: 0 - 70°C (ambient and sample temperature) Control Unit: 0 - 55°C ambient
Strorage temperature
-20°C to +60°C
System Protection
Detector and Junction Box: Designed to meet IP65. Salt fog immune. Control Unit: Designed to meet IP32.
Operating Voltage
24V DC (+30% -25%)
Power Consumption
Detector: 116mA Control Unit: 215mA
Protection
By self re-settable fuse inside Control Unit; Junction Box 4.0 amp fuse
Insulation
Flash tested to 2000V for 1 minute
Immunity to noise
System tested to requirements of classification societies including:
- Radiated susceptibility to radiated noise
- Conducted susceptibility to electrical noise
- Short duration supply interruption
- 1kV high frequency transient voltages
System Outputs
- Fault alarm: 1 set volt-free change-over relay contacts. Relay normally energised when system is powered. De-energises for fault or test condition.
- Main alarm: 1 set volt-free change-over relay contacts. Relay normally energised when system is powered. De-energises for alarm or test condition.
- Engine shutdown: 8 sets of volt-free change-over relay contacts. Relays normally de-energised when system is powered. Energises for alarm or test condition.
Back-up Alarm
1 set per engine mounted junction box.
Alarm Ranges
Average: 0.3mg/l to 1.3mg/l
Deviation: 0.05mg/l to 0.5mg/l
Back-up: 1.6mg/l fixed
Output relay contacts
30V 1A DC
System dimensions
(L x W x H)
Detector: 95 x 205 x 175
Junction Box: 318 x 186 x 90 (mm)
Control Unit: 500 x 313 x 118
(Bulkhead mounting) 619 x 369 x 118
(Panel mounting)
System weights (kg)
Detector: 0.6
Junction Box: 2.7
Control Unit: 6.6
Oil Mist detection, now widely accepted as a means of providing early warning of incipient bearing ..
$0.00 Ex Tax: $0.00
VAF Instruments Oilcon® Mark 6 MEPC.108(49) is used for the continuous online monitoring and contro..
The OMD-2005 Bilge Alarm Monitor was designed by Deckma Hamburg GmbH for use in conjunction with 15..
The OMD-2008 Bilge Alarm Monitor was designed by Deckma Hamburg GmbH for use in conjunction with 15..
The OMD-11 Bilge Alarm Monitor is an older unit, designed by Deckma Hamburg GmbH, for use in conjun..
The OMD-24 Bilge Alarm Unit has been designed specifically for use in conjunction with 15 ppm oil-w..
OMD-15 is designed for the special requirements on boiler water and condensate fiel..
The OMD-32 Oil-in-Water Monitor has been designed specifically for use in conjunction with oil-wate..
The OMD-21, 15ppm Bilge Alarm exceeds the requirements of IMO Resolution MEPC. 60 (33). With ..
OMD-7 MKII Industrial Monitor designed to measure the content of Free Oils, Suspended Solids and Tu..
The “SmartCell” oil content monitor meets the requirements of MEPC 107 (49) for monitoring of..
..
Maker : Daihatsu Model : MD-9MRange : 0-15 LED DisplaySupply Voltage : 24VDCAlarm Contact : Tro..
Maker : Daihatsu Model : MD-14Range : 0-15 LED DisplaySupply Voltage : 115VAC, 230VACAlarm Cont..
VISATRON VN 215/87plus operates in a similar same way like type VN 116/87plus when it comes to a Hig..
MD-SX oil mist detector, which consists of multiple sensor units that are directly inserted through ..
QMI MULTIPLEX OIL MIST DETECTOR Features Provides rapid 500 millisecond resp..